As rack densities climb and AI, HPC, and ML workloads push thermal output higher, data center liquid cooling has moved from a niche solution to a core infrastructure requirement. Traditional air cooling can’t keep pace with the heat generated by today’s high-density server racks. Belimo’s control solutions (actuators, valves, and sensors) are engineered specifically for the demands of liquid-cooled data center infrastructure, delivering the precision, scalability, and real-time data facility managers need to protect mission-critical equipment.
Below is a breakdown of the four primary liquid cooling applications Belimo supports, along with the core products that make them work.
Table of Contents
Why Data Center Liquid Cooling Systems Are Becoming Standard
Air-cooled systems have physical limits. Industry data backs this up: AI and HPC workloads are now routinely pushing rack densities past 30-50 kW, with some GPU clusters running well above 100 kW, compared to the 5-10 kW that traditional air-cooled racks were designed around. At that scale, air alone can’t move heat fast enough.
The shift is already well underway. AFCOM’s 2026 State of the Data Center Report found that average rack density hit 27 kW this year, up from 16 kW the year before. This is the steepest year-over-year jump in the report’s 10-year history, with 69% of respondents expecting density to keep climbing over the next 12 to 36 months. That pressure is showing up directly in cooling strategy. 36% of operators have liquid cooling deployed today, and another 28% plan to adopt it within the next 12 to 24 months.
Liquid cooling addresses the density problem by moving heat away from components using water or dielectric fluid, which transfers thermal energy far more efficiently than air. Belimo’s role in this shift is control. Precise, pressure-independent valves and sensors keep flow rates accurate across every liquid cooling method, even as system pressure and cooling demand change. This precision protects sensitive IT equipment while giving facility teams the real-time data needed to catch inefficiencies before they cause downtime.
Direct-to-Chip Cooling
Direct-to-chip liquid cooling is one of the most widely adopted methods for cooling servers with high thermal output, particularly in HPC, AI, and ML applications. Belimo’s Energy Valve, paired with differential pressure sensors, maintains constant differential pressure across the rack. This ensures precise coolant flow reaches each cold plate, even when a server is pulled for maintenance, so cooling performance never drops for the equipment that stays online.
Coolant Distribution Units (CDUs)
CDUs supply water-glycol mixes to cool heat-generating components like servers, acting as the interface between the facility’s cooling loop and the IT equipment. Belimo supports CDU applications with characterized control valves (CCVs), Energy Valves, and electronic pressure independent valves (EPIVs), all built for precise flow control that can scale as cooling demand grows without requiring a system overhaul.
Rear Door Heat Exchangers (RDHx)
RDHx is a popular entry point into liquid cooling because it can often be added to existing racks without the extensive plumbing changes other methods require. But that ease of deployment only pays off if the flow control behind it is precise—coolant flow has to match the exact heat load coming off the back of the rack in real time. Belimo’s EPIV and CCV valves provide the reliable, precise flow control RDHx systems need to perform consistently, rack after rack.
Immersion Cooling
Two-phase immersion cooling submerges components directly in dielectric fluid, and the system depends on precise water flow to condense that fluid effectively. Belimo’s EPIVs maintain consistent coil flow even through system pressure fluctuations. The Belimo Energy Valve adds another layer of insight here, continuously monitoring supply and return water temperatures, calculating thermal energy, and surfacing the data needed to track performance and catch inefficiencies early.
The Belimo Components Behind Every Data Center Liquid Cooling Application
A few core Belimo products show up across all four liquid cooling methods:
Belimo Energy Valve™
Combines pressure-independent control with built-in analytics, continuously monitoring flow, temperature, and energy consumption. Used across direct-to-chip, CDU, and immersion cooling applications.
-
EV100+AKRX-E
-
EV100+LRX-E N4
-
EV200H+ARX-E
-
EV125+AKRX-E
-
EV150+NRX-E N4
-
EV125+NRX-E N4
-
EV075+LRX-E N4
-
EV200H+AKRX-E N4
-
EV200+AKRX-E N4
-
EV150+AKRX-E N4
-
EV125+AKRX-E N4
-
EV100+AKRX-E N4
-
EV075+AKRX-E N4
-
EV050+AKRX-E N4
-
EV600SU-713-250+GRX24-EV
-
EV600SU-713-250+GKRX24-EV
-
EV600SU-713+GRX24-EV
-
EV600SU-713+GKRX24-EV
Electronic Pressure Independent Valve (EPIV)
Delivers precise flow control and automatic hydronic balancing regardless of pressure fluctuations, reducing commissioning time across CDU, RDHx, and immersion cooling systems.
-
Z2050QPT-D+CQB24-SR-R
-
Z2075QPT-G+CQX24-SR
-
Z2075QPT-G+CQKB24-SR-RR
-
Z2075QPT-G+CQB24-SR-R
-
Z2050QPT-F+CQX24-3
-
Z2050QPT-F+CQX24-SR
-
P3075B6-J+LRX24-LP-EP6
-
P2200SU-1000+ARX24-EP2-MOD
-
P2125SU-285+NRX24-EP2
-
P2050SU-055+AKRX24-EP2
-
EP100P6+NRX-E
-
EP100P6+NRTX-E HH2
-
EP100P6+NRTX-E HH1
-
EP075P6+LRX-E
-
EP075P6+LRTX-E HH2
-
EP075P6+LRTX-E HH1
-
EP050P6+LRX-E
-
EP050P6+LRTX-E HH2
Characterized Control Valve (CCV)
Compact 2- and 3-way valves with characterized discs and energy-efficient rotary actuators, built for accurate modulation and tight shutoff in CDU, RDHx, and header applications.
Differential Pressure Sensors and Flow Meters
Provide the real-time data that keeps direct-to-chip and immersion systems balanced under changing loads
Built for the Next Generation of Data Center Liquid Cooling Infrastructure
As rack densities rise and computing power increases, liquid cooling technologies are becoming essential for next-generation data centers. Belimo’s control solutions for direct-to-chip cooling, RDHx, immersion systems, and CDUs deliver the accuracy, responsiveness, and system transparency modern IT infrastructure requires—supporting scalable, high-efficiency cooling as your data center’s needs grow.
Looking to spec Belimo controls into a liquid cooling system? Contact Boston Aircontrols to talk through the right valves and sensors for your application.