SGF24
This product is no longer available. Please see our other products in this category.
Positioner for front-panel mountingWeight | 1.5 lbs |
---|---|
Brand | Belimo |
- Protection class IEC/EN
- III safety extra-low voltage (selv)
- Degree of protection IEC/EN
- IP40
- Mode of operation
- Type 1
- Material short text
- Positioner for front-panel mounti
- Actuator family
- Electronic Accessory
- Introductory text
- For front-panel mounting
- Accessories title
- Positioner
- Accessories text
- Positioner for front-panel mounting 0…100% operating range selectable DC 0...10 V or DC 2...10 V
- Accessories, miscellaneous
- 0…100%|operating range selectable|DC 0...10 V or DC 2...10 V
- Accessories use
- for front-panel mounting
- Mounting instruction
- https://www.belimo.com/pim/mam/europe/technical-documentation/Installation instruction/70081.C_SGA24_SGF24.pdf
- Product family
- Electrical Accessory
- NA Product type
- S - Sensors
- Structure Level1
- Valves
- Structure Level2
- Accessories
- Ambient temperature
- -4...122°F [-20...50°C]
- Non-operating temperature
- -40...176°F [-40...80°C]
- Ambient humidity
- max. 95% r.H. non-condensing
- Maintenance
- maintenance free
- Control operating range Y note
- Operating range selectable DC 0...10V or DC 2...10 V
- Positioning signal Y note
- DC 0...10 V switchable with slide switch
- Nominal voltage
- AC/DC 24 V
- Nominal voltage AC
- 24 V
- Nominal voltage DC
- 24 V
- Nominal voltage frequency
- 50/60 Hz
- Connection
- terminals
- Connection supply / control
- terminals 1.5 mm²
- Nominal voltage range
- AC 19.2...28.8 V / DC 19.2...28.8 V
- Notes box electrical installation
- Connection via safety isolating transformer.
- Connection Cable
- NO
- Accessory type
- Electrical accessory
- Non-Spring
- GMB(X)|AMB(X)|NMB(X)|LMB(X)|CMB|AHB(X)|LHB(X)|LUB(X)
- Electronic fail-safe
- AHKX|NKQB(X)
- Spring
- EFB(X)|AF|NF|TFB(X)|LF
- Power consumption in operation
- 0.3 W
- Power consumption in operation [Range]
- 0.3 W
- Easy switching
- The switching from DC 2 ... 10 V to DC 0 ... 10 V is accomplished by means of a slide switch on the printed circuit board.
- Application
- The positioner is used for the (remote) control of modulating damper actuators or as a minimum positioner (lower limitation of output signals from modulating controllers). The adjustment range is 0 ... 100% angle of rotation of the connected actuator.
- Safety notes
- The device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. The device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user. The device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed.