22HT-52

$97.65

Each

Contact Temperature Sensor active, 0…5 V, 0…10 V

or sign up for a free membership to get our lowest pricing.

Weight 0.33 lbs
Application

Pipe

Brand

Belimo

Sensor type

temperature

Output signal

0…10 V, 0…5 V

Measuring range temperature active note
Active sensor: range selectable|Attention: max. measuring temperature is restricted by max. medium temperature (see Safety data)
Jumper setting note
the adjustment of the measuring ranges is made by changing the bonding jumpers|the output value in the new measuring range is available after 2 seconds
Accuracy temperature active
±0.9°F @ 70°F [±0.5°C @ 21°C]
Cable gland
PA6, black
Medium temperature
-30...160°F [-35...70°C]
Ambient temperature
-30...120°F [-35...50°C]
Output signal active temperature
DC 0...5 V|DC 0...10 V
Output signal active note
output DC 0...5/10 V with jumper adjustable|voltage output: min. 5 kΩ load
Power supply DC
15...24 V
Power supply tolerance DC
±10%
Power consumption DC
0.42 W
Power supply AC
24 V
Power supply tolerance AC
±10%
Power consumption AC
0.84 VA
Measuring values
temperature
Sensor type
temperature
Housing type
Surface
Application
Pipe
Sensor powertype
active
Cable entry
Cable gland with strain relief Ø6...8 mm (1/2" NPT conduit adapter included)
Electrical connection
Removable spring loaded terminal block max. 2.5 mm²
Ambient humidity
max. 95% r.H. non-condensing
Scope of delivery
1/2" NPT conduit adapter
Mounting instruction
01HT, 22HT US Mounting Instruction Sheet
Degree of protection IEC/EN
IP65
Degree of protection NEMA/UL
NEMA 4X
Degree of Protection
IP65, NEMA 4X
Certification IEC/EN
IEC/EN 60730-1
Certification UL
cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1:02/-2-9
Protection class IEC/EN
III protective extra-low voltage (pelv)
Protection class UL
UL Class 2 Supply
Quality Standard
ISO 9001
Material short text
Housing Contact Temp Sensor V
Output signal
DC 0...5 V DC 0...10 V
Housing
cover: lexan, orange|base: lexan, orange|seal: 0467 NBR70, black
Multirange
8 fields selectable
Optional accessories
A-22P-A40|A-22P-A42|A-22P-A44
Electrical connection note
Removable spring loaded terminal block max. 2.5 mm²
Connection
terminals
Product family
Sensor
CAD data 3D
Belimo_22HT-12_3D.dwg|Belimo_22HT-12_3D.dxf|Belimo_22HT-12_3D.igs|Belimo_22HT-12_3D.sat|Belimo_22HT-12_3D.stp
Setting range S0 [°C]
-50...50°C
Setting range S0 [°F]
-30...130°F
Setting range S1 [°C]
-10...120°C
Setting range S1 [°F]
0...250°F
Setting range S2 [°C]
0...50°C
Setting range S2 [°F]
40...140°F
Setting range S3 [°C]
0...250°C
Setting range S3 [°F]
30...480°F
Setting range S4 [°C]
-15...35°C
Setting range S4 [°F]
0...100°F
Setting range S5 [°C]
0...100°C
Setting range S5 [°F]
40...240°F
Setting range S6 [°C]
-20...80°C
Setting range S6 [°F]
40...90°F
Setting range S7 [°C]
0...160°C
Setting range S7 [°F]
0...150°F
Mounting type pipe
Strap-on
Housing surface temperature
max. 160°F [70°C]
Application text
Active surface contact temperature sensor (0 to 5/10 V) for pipe applications. Spring loaded brass contact to ensure fast response and accurate readings. NEMA 4X / IP65 rated enclosure. [Pipe clamp included.]
General caution
The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
Additional caution
Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual

Installation instructions Download: Installation instructions

Need Help?

Call one of our experts 1-888-423-2525

Monday-Friday EST 6:00am - 4:00pm