22HH-500X

$141.75

Each

Condensation Sensor active, switch, External sensor, LED

or sign up for a free membership to get our lowest pricing.

Weight 0.44 lbs
Application

Condensation

Brand

Belimo

Sensor type

humidity

Output signal

switch

Cable gland
PA6, black
Medium temperature
-5...140°F [-20...60°C]
Ambient temperature
-5...120°F [-20...50°C]
Power supply DC
15...24 V
Power supply tolerance DC
±10%
Power consumption DC
0.8 W
Power supply AC
24 V
Power supply tolerance AC
±10%
Power consumption AC
1.6 VA
Display
LED green - power supply ok red - dew permeation
Display type
LED
Display note
green - power supply ok|red - dew permeation
Measuring values
condensation
Sensor type
humidity
Housing type
Housing Surface
Application
Condensation
Cable entry
Cable gland with strain relief Ø6...8 mm (1/2" NPT conduit adapter included)
Electrical connection
Removable spring loaded terminal block max. 2.5 mm²
Ambient humidity
max. 95% r.H. non-condensing
Scope of delivery
Mounting plate|Cable tie|1/2" NPT conduit adapter
Mounting instruction
22HH, 22HH-..X US Mounting Instruction Sheet
Degree of protection IEC/EN
IP65
Degree of Protection
IP65,
Certification IEC/EN
IEC/EN 60730-1
Certification UL
cULus acc. to UL60730-1A/-2-9/-2-13, CAN/CSA E60730-1:02/-2-9
Protection class IEC/EN
III safety extra-low voltage (selv)
Protection class UL
UL Class 2 Supply
Quality Standard
ISO 9001
Material short text
Humidity Switch EXT
Output signal
switch
Housing
cover: lexan, orange|base: lexan, orange|seal: 0467 NBR70, black
Optional accessories
A-22P-A44
Electrical connection note
Removable spring loaded terminal block max. 2.5 mm²
Connection
terminals
Product family
Sensor
CAD data 3D
Belimo_22HH-100X_3D.dwg|Belimo_22HH-100X_3D.dxf|Belimo_22HH-100X_3D.igs|Belimo_22HH-100X_3D.sat|Belimo_22HH-100X_3D.stp
Output signal switch note
changeover contact, isolated; max. 24 V / 1.0 A (resistive)
Cable length
6.5 ft. [2 m]
Application text
Condensation sensor with LED signal. Designed to provide a switched output signal to prevent condensation on chilled surfaces such as chilled beams. NEMA 4X / IP65 rated enclosure. Also available direct mounted and without 6 ft/2 m remote cable.
General caution
The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
Additional caution
Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual

Installation instructions Download: Installation instructions

Need Help?

Call one of our experts 1-888-423-2525

Monday-Friday EST 6:00am - 4:00pm