01ST-5A3

$29.70

Each

Contact Temperature Sensor passive, Pt100, Probe diameter 0.24″ [6 mm], cable 6.5 ft. [2 m], 2-wire

or sign up for a free membership to get our lowest pricing.

Weight 0.13 lbs
Application

Pipe

Brand

Belimo

Sensor type

temperature

Output signal

Pt100

Measuring range temperature
-30...210°F [-35...100°C]
Accuracy temperature passive
passive sensors depending on used type Pt.. = ±0.5°F @ 32°F [±0.3°C @ 0°C] Ni.. = ±0.7°F @ 32°F [±0.4°C @ 0°C] NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]
Medium temperature
-30...210°F [-35...100°C]
Ambient temperature
-30...210°F [-35...100°C]
Output signal passive temperature
Pt1000|Ni1000 (JCI)|NTC10k2|NTC10k3|NTC20k
Probe diameter
0.24" [6 mm]
Application text
Surface contact mounted temperature sensor for pipe and arched surfaces. Plenum rated cable and a brass probe for fast response and accuracy and NEMA 4 / IP65 rated. [Pipe clamp included.]
Measuring values
temperature
Sensor type
temperature
Housing type
Surface
Application
Pipe
Sensor powertype
passive
Electrical connection
cable 6.5 ft. [2 m], 2-wire
Ambient humidity
max. 95% r.H. non-condensing
Mounting instruction
01ST US Mounting Instruction Sheet
Degree of protection IEC/EN
IP65
Degree of protection NEMA/UL
NEMA 4
Degree of Protection
IP65, NEMA 4
Certification IEC/EN
IEC/EN 60730-1
Certification UL
cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1:02/-2-9
Protection class IEC/EN
III safety extra-low voltage (selv)
Protection class UL
UL Class 2 Supply
Quality Standard
ISO 9001
Material short text
Contact Temp Sensor PT100 2m
Output signal
Pt100
Optional accessories
A-22P-A40|A-22P-A42|A-22P-A44
Electrical connection note
2-wire
Connection
cable
Product family
Sensor
CAD data 3D
Belimo_01ST-1A3_3D.dwg|Belimo_01ST-1A3_3D.dxf|Belimo_01ST-1A3_3D.igs|Belimo_01ST-1A3_3D.sat|Belimo_01ST-1A3_3D.stp
Cable length
6.5 ft. [2 m]
Mounting type pipe
Strap-on
General caution
The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
Additional caution
Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual

Installation instructions Download: Installation instructions

Need Help?

Call one of our experts 1-888-423-2525

Monday-Friday EST 6:00am - 4:00pm