22ADP-554L

$290.70

Each

Differential Pressure Sensor Air, 0…10 inch WC [0…2500 Pa], Modbus, LCD

or sign up for a free membership to get our lowest pricing.

Weight 0.68 lbs
Application

Duct

Brand

Belimo

Sensor type

pressure

Output signal

Modbus

Communicative
communicative
Communicative control
Modbus RTU
Calibration
automatic zero-point calibration (optional)
Sensor Technology
piezo measuring element
Cable gland
PA6, black
Medium temperature
15...120°F [-10...50°C]
Ambient temperature
15...120°F [-10...50°C]
Output signal active note
Output DC 0...5/10 V selectable with switch|voltage output: min. 10 kΩ load|current output: max. 500 Ω load
Power supply DC
15...24 V
Power supply tolerance DC
±10%
Power consumption DC
1.4 W
Power supply AC
24 V
Power supply tolerance AC
±10%
Power consumption AC
2 VA
Display
LCD, 1.14x1.38" [29x35 mm] with backlight measured values: Pa, inchWC (configurable) measured values volumetric flow: m³/h, cfm (configurable)
Display type
LCD
Display size
1.14x1.38" [29x35 mm]
Display note
with backlight|measured values: Pa, inchWC (configurable)|measured values volumetric flow: m³/h, cfm (configurable)
Mounting type duct
Single Point
Measuring values
differential pressure
Sensor type
pressure
Housing type
Duct
Application
Duct
Sensor powertype
active
Communication
Modbus RTU
Cable entry
Cable gland with strain relief 2 x Ø6 mm (1/2" NPT conduit adapter included)
Electrical connection
Removable spring loaded terminal block max. 2.5 mm²
Ambient humidity
max. 95% r.H. non-condensing
Scope of delivery
Mounting plate|Dowel|Screws|Strain relief Ø6...8 mm|1/2" NPT conduit adapter, 2 x Ø6 mm|Cable Gland Nut PG11, Ø6...10 mm|1/2" NPT conduit adapter
Mounting instruction
Mounting Instruction - 71967-00001B 22ADP-..5-..6|Sensor Modbus-Register
Degree of protection IEC/EN
IP65
Degree of Protection
IP65,
Certification IEC/EN
IEC/EN 60730-1
Certification UL
cULus acc. to UL60730-1A/-2-6, CAN/CSA E60730-1:02
Protection class IEC/EN
III safety extra-low voltage (selv)
Protection class UL
UL Class 2 Supply
Quality Standard
ISO 9001
Material short text
Diff Air Pressure Sensor 2500 LCD MOD
Output signal
Modbus
Housing
cover: lexan, orange|base: lexan, orange|seal: 0467 NBR70, black
Multirange
8 fields selectable
Optional accessories
A-22AP-A01|A-22AP-A03
Electrical connection note
Removable spring loaded terminal block max. 2.5 mm²
Connection
terminals
Product family
Sensor
CAD data 3D
Belimo_22ADP-154L_3D.dwg|Belimo_22ADP-154L_3D.dxf|Belimo_22ADP-154L_3D.igs|Belimo_22ADP-154L_3D.sat|Belimo_22ADP-154L_3D.stp
Measuring range diff. pressure
0...10 inch WC
Accuracy pressure
measuring range ≤2 inch WC (500 Pa): ±0.02 inch WC (±5 Pa)|measuring range >2 inch WC (500 Pa): ±0.04 inch WC (±10 Pa)
Measuring media
air and non-aggressive gases
Overpressure range
40 kPa / 160 inch WC
Setting range S0 [Pa]
0...2500
Setting range S0 ["wc]
0...10
Setting range S1 [Pa]
0...2000
Setting range S1 ["wc]
0...8
Setting range S2 [Pa]
0...1500
Setting range S2 ["wc]
0...6
Setting range S3 [Pa]
0...1000
Setting range S3 ["wc]
0...4
Setting range S4 [Pa]
0...500
Setting range S4 ["wc]
0...2
Setting range S5 [Pa]
0...250
Setting range S5 ["wc]
0...1
Setting range S6 [Pa]
0...100
Setting range S6 ["wc]
0...0.4
Setting range S7 [Pa]
-100...100
Setting range S7 ["wc]
-0.4...0.4
Output signal active pressure
DC 0...5 V|DC 0...10 V
Output signal active volumetric flow
DC 0...5 V|DC 0...10 V
RS485 documentation
The separate document Sensor Modbus-Register informs about Modbus register, addressing, parity and bus termination (DIP1: address, DIP2: baud rate, parity, bus termination) In addition to the information on the bus, the following analog outputs are available: AOU1: differential pressure AOU2: volumetric flow The volumetric flow is calculated from the differential pressure, the k-factor and the height Factory setting for the k-factor is 1.00 and for the height 330 metres above sea level. The values of the k-factor and the height can be changed via Modbus or BACnet.
Notes box electrical installation
Connection via safety isolating transformer. Parallel power connection of additional devices possible. Observe the performance data. The wiring of the line for BACnet MS/TP / Modbus RTU is to be carried out in accordance with applicable RS485 regulations. Modbus / BACnet: Supply and communication are not galvanically isolated. Connect earth signal of the devices with one another.
Application text
Differential pressure transmitter with 8 selectable ranges and 0 to 5/10 V, 4 to 20 mA outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the differential pressure of air and other non-flammable and non-aggressive gases. Monitoring air filters, fans, industrial cooling air cycles, control of air and fire dampers.
General caution
The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
Additional caution
Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual
Measuring range settings pressure
Settingrange [Pa]range [inch WC]Factory setting
S00...25000...10Yes
S10...20000...8No
S20...15000...6No
S30...10000...4No
S40...5000...2No
S50...2500...1No
S60...1000...0.4No
S7-100...100-0.4...0.4No
Manual Zero-Point calibration
In normal operation zero-point calibration should be executed every 12 months. Attention! For executing zero point calibration the power supply must be connected one hour before. • Release both connection tubes from the pressure terminals + and - • Press the button until the LED lights permanently • Wait until the LED flashes again and reinstall the connection tubes to the pressure ports (note + and -)

Installation instructions Download: Installation instructions

Need Help?