- Measuring range temperature
- Pt.., Ni.. : -30...160°F [-35...70°C]|NTC.. : -30...120°F [0...50°C]
- Accuracy temperature passive
- passive sensors depending on used type Pt.. = ±0.5°F @ 32°F [±0.3°C @ 0°C] Ni.. = ±0.7°F @ 32°F [±0.4°C @ 0°C] NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]
- Cable gland
- PA6, black
- Medium temperature
- Pt.., Ni.. : -30...160°F [-35...70°C] NTC.. : 30...120°F [0...50°C]
- Ambient temperature
- -30...120°F [-35...50°C]
- Output signal passive temperature
- Pt1000|Ni1000 (JCI)|NTC10k2|NTC10k3|NTC20k
- Probe length
- 20 ft [6 m]
- Mounting type duct
- Averaging
- Measuring values
- temperature
- Sensor type
- temperature
- Housing type
- Duct
- Application
- Duct
- Sensor powertype
- passive
- Cable entry
- Cable gland with strain relief Ø6...8 mm (1/2" NPT conduit adapter included)
- Electrical connection
- Removable spring loaded terminal block max. 2.5 mm²
- Ambient humidity
- max. 95% r.H. non-condensing
- Scope of delivery
- 1/2" NPT conduit adapter
- Mounting instruction
- Mounting instruction - 71960-00001A 01MT 22MT
- Degree of protection IEC/EN
- IP65
- Degree of Protection
- IP65,
- Certification IEC/EN
- IEC/EN 60730-1
- Certification UL
- cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1:02/-2-9
- Protection class IEC/EN
- III safety extra-low voltage (selv)
- Protection class UL
- UL Class 2 Supply
- Quality Standard
- ISO 9001
- Material short text
- Duct Average Temp Sensor NTC10kP 6m
- Output signal
- NTC10K3
- Housing
- UV resistant|cover: lexan, orange|base: lexan, orange|seal: 0467 NBR70, black
- Electrical connection note
- Removable spring loaded terminal block max. 2.5 mm²
- Connection
- terminals
- Product family
- Sensor
- CAD data 3D
- Belimo_01MT-5.._3D.stp
- Housing surface temperature
- max. 195°F [90°C]
- Time constant t (63%) in the air duct
- typical 100 s @ 0 m/s with probe length 3 m|typical 100 s @ 0 m/s with probe length 6 m
- General remarks sensors
- Due to self-heating with 2 wire passive sensors, the supply wire current affects the measurement accuracy, so it should not exceed 1 mA. When using lengthy connection wires (depending on the cross section used) the measuring result might be falsified due to a voltage drop at the common GND-wire (caused by the voltage current and the line resistance). In this case, 2 GND-wires must be wired to the sensor - one for supply voltage and one for the measuring current.
- Application text
- PT1000 version is supplied with one continuous sensing element across the whole length of the probe to ensure optimum accuracy and eliminate air stratification problems. NTC and Ni1000 are industry standard multi-point sensing elements.
- General caution
- The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
- Additional caution
- Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual
Datasheet Download: Datasheet
Installation instructions Download: Installation instructions