- Measuring range temperature
- 15...60°F [-10...15°C]
- Jumper setting note
- set point range (factory setting 41°F [5°C])
- Accuracy temperature active
- ±0.9°F [±0.5°C]
- Accuracy temperature passive
- ±0.9°F [±0.5°C]
- Cable gland
- PA6, black
- Medium temperature
- -30...160°F [-35...70°C]
- Ambient temperature
- -30...160°F [-35...70°C]
- Probe material
- copper/vapor filled R507
- Probe length
- 20 ft [6 m]
- Mounting type duct
- Single Point
- Measuring values
- temperature
- Sensor type
- temperature
- Housing type
- Duct
- Application
- Low temperature detection
- Cable entry
- Cable gland cap nut with strain relief Ø6...8 mm
- Ambient humidity
- max. 95% r.H. non-condensing
- Scope of delivery
- Installation kit
- Mounting instruction
- Mounting instruction - 71938-00001D 01DTS
- Degree of protection IEC/EN
- IP65
- Degree of protection NEMA/UL
- NEMA 4
- Degree of Protection
- IP65, NEMA 4
- Certification IEC/EN
- IEC/EN 60730-1
- Protection class IEC/EN
- III protective extra-low voltage (pelv)
- Quality Standard
- ISO 9001
- Material short text
- Frost Sensor 6m
- Output signal
- switch
- Housing
- base: PA6 GK30, light gray|seal: 0467 NBR70, black|cover ABS, transparent
- Connection
- terminals
- Product family
- Sensor
- CAD data 3D
- Belimo_01DTS-105X_3D.dwg|Belimo_01DTS-105X_3D.dxf|Belimo_01DTS-105X_3D.igs|Belimo_01DTS-105X_3D.sat|Belimo_01DTS-105X_3D.stp
- Output signal switch note
- single pole change over, switching load max. 10 A (DC 250 V)
- Output signal temperature switch
- changeover
- Output signal temperature switch note
- single pole change over, switching load max. 10 A (DC 250 V)
- Application text
- Low temperature detection sensor, also known as "Freeze Stats". For temperature monitoring on HVAC equipment that requires low-temperature cutout protection to prevent cooling coils from freezing. Manual or automatic reset versions available as well as various capillary lengths.
- General caution
- The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
- Electrical caution
- During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.
- Additional caution
- Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual
Datasheet Download: Datasheet
Installation instructions Download: Installation instructions