01DTS-505

$164.70

Each

Low Temperature Detection Sensor active, switch, Auto reset

or sign up for a free membership to get our lowest pricing.

Weight 1.01 lbs
Application

Frost detection

Brand

Belimo

Sensor type

temperature

Output signal

switch

Measuring range temperature
15...60°F [-10...15°C]
Jumper setting note
set point range (factory setting 41°F [5°C])
Accuracy temperature active
±0.9°F [±0.5°C]
Accuracy temperature passive
±0.9°F [±0.5°C]
Cable gland
PA6, black
Medium temperature
-30...160°F [-35...70°C]
Ambient temperature
-30...160°F [-35...70°C]
Probe material
copper/vapor filled R507
Probe length
20 ft [6 m]
Mounting type duct
Single Point
Measuring values
temperature
Sensor type
temperature
Housing type
Duct
Application
Low temperature detection
Cable entry
Cable gland cap nut with strain relief Ø6...8 mm
Ambient humidity
max. 95% r.H. non-condensing
Scope of delivery
Installation kit
Mounting instruction
Mounting instruction - 71938-00001D 01DTS
Degree of protection IEC/EN
IP65
Degree of protection NEMA/UL
NEMA 4
Degree of Protection
IP65, NEMA 4
Certification IEC/EN
IEC/EN 60730-1
Protection class IEC/EN
III protective extra-low voltage (pelv)
Quality Standard
ISO 9001
Material short text
Frost Sensor 6m RS
Output signal
switch
Housing
base: PA6 GK30, light gray|seal: 0467 NBR70, black|cover ABS, transparent
Connection
terminals
Product family
Sensor
CAD data 3D
Belimo_01DTS-105_3D.dwg|Belimo_01DTS-105_3D.dxf|Belimo_01DTS-105_3D.igs|Belimo_01DTS-105_3D.sat|Belimo_01DTS-105_3D.stp
Output signal switch note
single pole change over, switching load max. 10 A (DC 250 V)
Output signal temperature switch
changeover
Output signal temperature switch note
single pole change over, switching load max. 10 A (DC 250 V)
Application text
Low temperature detection sensor, also known as "Freeze Stats". For temperature monitoring on HVAC equipment that requires low-temperature cutout protection to prevent cooling coils from freezing. Manual or automatic reset versions available as well as various capillary lengths.
General caution
The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
Electrical caution
During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.
Additional caution
Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual

Installation instructions Download: Installation instructions

Need Help?

Call one of our experts 1-888-423-2525

Monday-Friday EST 6:00am - 4:00pm