01DT-5ER

$20.70

Each
Duct / Immersion Temperature Sensor passive, Ni1000 (JCI), Probe length 12" [300 mm], Probe diameter 0.24" [6 mm]

or sign up for a free membership to get our lowest pricing.

Weight 0.31 lbs
Application

Duct, Pipe

Brand

Belimo

Sensor type

temperature

Output signal

Ni1000 (JCI)

Measuring range temperature
-60...320°F [-50...160°C]
Accuracy temperature passive
±0.7°F @ 32°F [±0.4°C @ 0°C]
Cable gland
plug adapter: PA66, black|nut: PA6, black
Medium temperature
-60...320°F [-50...160°C]
Ambient temperature
-30...120°F [-35...50°C]
Output signal passive temperature
Ni1000 (JCI)
Probe diameter
0.24" [6 mm]
Probe length
12" [300 mm]
Mounting type duct
Single Point
Measuring values
temperature
Sensor type
temperature
Housing type
Duct
Application
Duct|Pipe
Sensor powertype
passive
Cable entry
Cable gland with strain relief Ø6...8 mm (1/2" NPT conduit adapter included)
Electrical connection
Removable spring loaded terminal block max. 2.5 mm²
Ambient humidity
max. 95% r.H. non-condensing
Scope of delivery
1/2" NPT conduit adapter
Mounting instruction
Mounting instruction - 71955-00001.E 01DT 22DT
Degree of protection IEC/EN
IP65
Degree of Protection
IP65,
Certification IEC/EN
IEC/EN 60730-1
Certification UL
cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1:02/-2-9
Protection class IEC/EN
III safety extra-low voltage (selv)
Protection class UL
UL Class 2 Supply
Quality Standard
ISO 9001
Material short text
Duct Temp Sensor Ni891 300x6
Output signal
Ni1000 (JCI)
Housing
UV resistant|cover: lexan, orange|base: lexan, orange|seal: 0467 NBR70, black
Optional accessories
A-22G-A04.1
Recommended accessories water
A-22P-A05|A-22P-A07|A-22P-A09|A-22P-A11|A-22P-A13|A-22P-A15|A-22P-A36|A-22P-A37|A-22P-A38|A-22P-A39|A-22P-A17|A-22P-A19|A-22P-A21|A-22P-A23|A-22P-A25|A-22P-A27|A-22P-A44
Electrical connection note
Removable spring loaded terminal block max. 2.5 mm²
Connection
terminals
Product family
Sensor
CAD data 3D
Belimo_01DT-5..R_3D.stp
Mounting type pipe
Immersion
Housing surface temperature
max. 195°F [90°C]
SI Protection
YES
Optional accessories air
A-22D-A03|A-22D-A05
Time constant t (63%) in the air duct
typical 210 s @ 0 m/s|typical 46 s @ 3 m/s
Time constant t (63%) in water pipe
with thermowell A-22P-A.. and thermal contact fluid|typical 7 s with thermowell brass|typical 9 s with thermowell stainless steel
General remarks sensors
Due to self-heating with 2 wire passive sensors, the supply wire current affects the measurement accuracy, so it should not exceed 1 mA. When using lengthy connection wires (depending on the cross section used) the measuring result might be falsified due to a voltage drop at the common GND-wire (caused by the voltage current and the line resistance). In this case, 2 GND-wires must be wired to the sensor - one for supply voltage and one for the measuring current.
Application text
Duct/Immersion temperature sensor for duct and pipe applications. NEMA 4X / IP65 rated enclosure. Various stainless steel probe lengths available. Stainless steel or brass thermowell pockets should be purchased with sensors intended for immersion applications.
General caution
The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
Additional caution
Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual

Installation instructions Download: Installation instructions

Need Help?

Call one of our experts 1-888-423-2525