01CT-5QH
$18.00
EachCable Temperature Sensor passive, NTC20K, Probe diameter 0.24″ [6 mm], cable 6.5 ft. [2 m], 2-wire
Weight | 0.14 lbs |
---|---|
Application | Cable |
Brand | Belimo |
Sensor type | temperature |
Output signal | NTC20K |
- Measuring range temperature
- -30...210°F [-35...100°C]
- Accuracy temperature passive
- passive sensors depending on used type Pt.. = ±0.5°F @ 32°F [±0.3°C @ 0°C] Ni.. = ±0.7°F @ 32°F [±0.4°C @ 0°C] NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]
- Medium temperature
- -30...210°F [-35...100°C]
- Ambient temperature
- -30...210°F [-35...100°C]
- Output signal passive temperature
- Pt100|Pt1000|Ni1000 (JCI)|NTC10k2|NTC10k3|NTC20k
- Probe diameter
- 0.24" [6 mm]
- Probe length
- 2" [50 mm]
- Application text
- Passive cable type temperature sensor for measuring the temperature in pipe and air applications. Incorporates a stainless steel probe and plenum rated cable.
- Measuring values
- temperature
- Sensor type
- temperature
- Housing type
- Cable
- Application
- Cable
- Sensor powertype
- passive
- Cable specification
- 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40°F to 300°F (-40°C to 150°C), 300 V
- Electrical connection
- cable 6.5 ft. [2 m], 2-wire
- Ambient humidity
- max. 95% r.H. non-condensing
- Mounting instruction
- 01CT US Mounting Instruction Sheet
- Degree of protection IEC/EN
- IP67
- Degree of protection NEMA/UL
- NEMA 4X
- Degree of Protection
- IP67, NEMA 4X
- Certification IEC/EN
- IEC/EN 60730-1
- Certification UL
- cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1:02/-2-9
- Protection class IEC/EN
- III safety extra-low voltage (selv)
- Protection class UL
- UL Class 2 Supply
- Quality Standard
- ISO 9001
- Material short text
- Cable Temp Sensor NTC20k 50x6 2m
- Output signal
- NTC20K
- Recommended accessories water
- A-22P-A44|A-22P-A45|A-22P-A40|A-22P-A42|A-22P-A44
- Electrical connection note
- 2-wire
- Connection
- cable
- Product family
- Sensor
- CAD data 3D
- Belimo_01CT-5.._3D.stp
- Cable length
- 6.5 ft. [2 m]
- SI Protection
- YES
- Optional accessories air
- A-22D-A03|A-22D-A05
- General caution
- The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
- Additional caution
- Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual
Datasheet Download: Datasheet
Installation instructions Download: Installation instructions
Need Help?
Call one of our experts 1-888-423-2525
Monday-Friday EST 6:00am - 4:00pm