01CT-5BP

$22.50

Each

Cable Temperature Sensor with mounting flange passive, Pt1000, Probe diameter 0.24″ [6 mm], cable 6.5 ft. [2 m], 2-wire

or sign up for a free membership to get our lowest pricing.

Weight 0.18 lbs
Application

Cable

Brand

Belimo

Sensor type

temperature

Output signal

Pt1000

Measuring range temperature
-30...210°F [-35...100°C]
Accuracy temperature passive
passive sensors depending on used type Pt.. = ±0.5°F @ 32°F [±0.3°C @ 0°C] NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]
Medium temperature
-30...210°F [-35...100°C]
Ambient temperature
-30...210°F [-35...100°C]
Output signal passive temperature
Pt1000|NTC10k2|NTC10k3|NTC20k
Probe diameter
0.24" [6 mm]
Probe length
8" [200 mm]
Application text
Cable type temperature sensor with adjustable rubber mounting flange for measuring temperature in FCU, AHU and VAV applications. Incorporates a stainless steel probe and plenum rated cable.
Measuring values
temperature
Sensor type
temperature
Housing type
Cable
Application
Cable
Sensor powertype
passive
Cable specification
1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40°F to 300°F (-40°C to 150°C), 300 V
Electrical connection
cable 6.5 ft. [2 m], 2-wire
Ambient humidity
max. 95% r.H. non-condensing
Scope of delivery
mounting flange
Mounting instruction
01CT US Mounting Instruction Sheet
Degree of protection IEC/EN
IP67
Degree of protection NEMA/UL
NEMA 4X
Degree of Protection
IP67, NEMA 4X
Certification IEC/EN
IEC/EN 60730-1
Certification UL
cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1:02/-2-9
Protection class IEC/EN
III safety extra-low voltage (selv)
Protection class UL
UL Class 2 Supply
Quality Standard
ISO 9001
Material short text
Cable Temp Sensor PT1000 200x6 2m
Output signal
Pt1000
Electrical connection note
2-wire
Connection
cable
Product family
Sensor
CAD data 3D
Belimo_01CT-5..L-P_3D.stp
Cable length
6.5 ft. [2 m]
SI Protection
YES
General caution
The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
Additional caution
Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual

Need Help?

Call one of our experts 1-888-423-2525

Monday-Friday EST 6:00am - 4:00pm