01DT-5BT
$31.95
EachDuct / Immersion Temperature Sensor passive, Pt1000, Probe length 18″ [450 mm], Probe diameter 0.24″ [6 mm]
Weight | 0.33 lbs |
---|---|
Application | Duct, Pipe |
Brand | Belimo |
Sensor type | temperature |
Output signal | Pt1000 |
- Measuring range temperature
- -60...320°F [-50...160°C]
- Accuracy temperature passive
- ±0.5°F @ 32°F [±0.3°C @ 0°C]
- Cable gland
- plug adapter: PA66, black|nut: PA6, black
- Medium temperature
- -60...320°F [-50...160°C]
- Ambient temperature
- -30...120°F [-35...50°C]
- Output signal passive temperature
- Pt1000
- Probe diameter
- 0.24" [6 mm]
- Probe length
- 18" [450 mm]
- Mounting type duct
- Single Point
- Measuring values
- temperature
- Sensor type
- temperature
- Housing type
- Duct
- Application
- Duct|Pipe
- Sensor powertype
- passive
- Cable entry
- Cable gland with strain relief Ø6...8 mm (1/2" NPT conduit adapter included)
- Electrical connection
- Removable spring loaded terminal block max. 2.5 mm²
- Ambient humidity
- max. 95% r.H. non-condensing
- Scope of delivery
- 1/2" NPT conduit adapter
- Mounting instruction
- Mounting instruction - 71955-00001.E 01DT 22DT
- Degree of protection IEC/EN
- IP65
- Degree of Protection
- IP65,
- Certification IEC/EN
- IEC/EN 60730-1
- Certification UL
- cULus acc. to UL60730-1A/-2-9, CAN/CSA E60730-1:02/-2-9
- Protection class IEC/EN
- III safety extra-low voltage (selv)
- Protection class UL
- UL Class 2 Supply
- Quality Standard
- ISO 9001
- Material short text
- Duct Temp Sensor PT1000 450x6
- Output signal
- Pt1000
- Housing
- UV resistant|cover: lexan, orange|base: lexan, orange|seal: 0467 NBR70, black
- Optional accessories
- A-22G-A04.1
- Recommended accessories water
- A-22P-A05|A-22P-A07|A-22P-A09|A-22P-A11|A-22P-A13|A-22P-A15|A-22P-A36|A-22P-A37|A-22P-A38|A-22P-A39|A-22P-A17|A-22P-A19|A-22P-A21|A-22P-A23|A-22P-A25|A-22P-A27|A-22P-A44
- Electrical connection note
- Removable spring loaded terminal block max. 2.5 mm²
- Connection
- terminals
- Product family
- Sensor
- CAD data 3D
- Belimo_01DT-1BT_3D.dwg|Belimo_01DT-1BT_3D.dxf|Belimo_01DT-1BT_3D.igs|Belimo_01DT-1BT_3D.sat|Belimo_01DT-1BT_3D.stp
- Mounting type pipe
- Immersion
- Housing surface temperature
- max. 195°F [90°C]
- SI Protection
- YES
- Optional accessories air
- A-22D-A03|A-22D-A05
- Time constant t (63%) in the air duct
- typical 210 s @ 0 m/s|typical 46 s @ 3 m/s
- Time constant t (63%) in water pipe
- with thermowell A-22P-A.. and thermal contact fluid|typical 7 s with thermowell brass|typical 9 s with thermowell stainless steel
- General remarks sensors
- Due to self-heating with 2 wire passive sensors, the supply wire current affects the measurement accuracy, so it should not exceed 1 mA. When using lengthy connection wires (depending on the cross section used) the measuring result might be falsified due to a voltage drop at the common GND-wire (caused by the voltage current and the line resistance). In this case, 2 GND-wires must be wired to the sensor - one for supply voltage and one for the measuring current.
- Application text
- Duct/Immersion temperature sensor for duct and pipe applications. NEMA 4X / IP65 rated enclosure. Various stainless steel probe lengths available. Stainless steel or brass thermowell pockets should be purchased with sensors intended for immersion applications.
- General caution
- The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
- Additional caution
- Please comply with • Local laws, health & safety regulations, technical standards and regulations • Condition of the device at the time of installation, to ensure safe installation • This data sheet and installation manual
Datasheet Download: Datasheet
Installation instructions Download: Installation instructions